TigerSelect Détecteur de gaz à photo-ionisation à sécurité intrinsèque - Intrinsically safe photo-ionisation gas detectorTigerSelect Détecteur de gaz à photo-ionisation à sécurité intrinsèque - Intrinsically safe photo-ionisation gas detector

Détecteur de gaz à photo-ionisation à sécurité intrinsèque TigerSelect

Détecteur de gaz à photo-ionisation à sécurité intrinsèque destiné à la détection de composés aromatiques et de Benzène - TIGER Select Ion Science Ltd
Description du produit

TigerSelect - Détecteur de gaz à photo-ionisation à sécurité intrinsèque - Ion Science Ltd

Benzene & Total Aromatic Compound (TAC) detector. Rapidly detects benzene and total aromatic compounds (TACs) providing the most accurate, reliable data available.

A revolutionary hand-held detector, Tiger Select has two basic modes of operation capable of detecting total aromatic compounds (TACs) without the tube attachment, or benzene with the Draeger pre-filter tube.
Utilising the high output Ion Science 10.0 eV detection system, a reading for total aromatic compounds (TACs) is seen immediately on start-up. Should aromatics be detected, a Draeger benzene pre-filter tube can be easily attached to ensure rapid detection and selective measurement of benzene. Tiger Select can also provide 15 minute short term exposure limits (STELs) and 8 hour time weighted averages (TWAs) for TACs.
Throughout the measurement process, Tiger Select continues to display real time data, ensuring the final reading represents the full value of actual benzene present. Benzene concentrations are displayed down to ppb levels, giving you the most accurate, reliable data you can count on.
In addition, the unique IonPIDTM VOC sensor incorporates both Anti-contamination technology and Fence Electrode technology for extended operation in difficult working environments.
Tiger Select can also be used in standard PhoCheck Tiger operational mode without the use of a benzene pre-filter tube to deliver active indications of volatile organic compounds (VOCs), including benzene at concentrations as low as 1 ppb benzene equivalent.

FEATURES & BENEFITS

- Best proven photoionisation detection (PID)
- Minimise downtime
- Ease of use
- Safety
- Low cost operation

Nos Services

Ma Commande

Modes de Livraison

Moyens de Paiement

Service après-vente

 

Aide

Rechercher un produit

Nous contacter

Plan du site

Conditions des Offres Promotionnelles

 

 

Ornicom Security products

© 1989 - 2016 Ornicom Tous Droits Réservés.
 
5550 Alle-sur-Semois Belgium
Tel:+32 61 48 01 50
Fax:+32 61 48 01 51
E-mail: Cette adresse e-mail est protégée contre les robots spammeurs. Vous devez activer le JavaScript pour la visualiser.
 
Méthodes de Paiement
SSL