ENSV6348415P - Centrale de Détection Incendie Adressable 4 Boucles Analogiques 48 Zones, 4 Loops Analogue Fire Control Panel 48 ZonesENSV6348415P - Centrale de Détection Incendie Adressable 4 Boucles Analogiques 48 Zones, 4 Loops Analogue Fire Control Panel 48 Zones

Centrale Detection Incendie SYNCRO 4 Boucles 48 Zones Grand boitier SYNCRO ENSV6348415P

Centrale de Détection Incendie Adressable 4 Boucles Analogiques 48 Zones avec protocole ARGUS VEGA Grand coffret + Imprimante Kentec SYNCRO ENSV6348415P
Description du produit

ENSV6348415P - Centrale de Détection Incendie Adressable 4 Boucles Analogiques 48 Zones Grand boitier avec Imprimante et Protocole ARGUS VEGA - Kentec SYNCRO

Available with 2 or 4 detection circuits, each capable of hosting up to 240 devices (Argus Vega). Syncro uses the most advanced microprocessor technology to provide a control system of extremely high integrity.
Syncro can be configured to suit all types of system, from the most simple, to the highly complex. Its fully integrated and secure network provides an intelligent interface for building control.
A large area graphic display ensures that information is presented in plain language with detailed extra help available by pressing a ‘help’ button.
Syncro supports three of the most widely used communication protocols produced by leading fire detector manufacturers and employs daily calibration routines to ensure that the system is always at optimum performance.

FEATURES & BENEFITS

- 2 or 4 loop versions as standard
- Larger enclosure available (fits 24A/H SLAs)
- Loopless panel option (repeater)
- 0, 16, 48, or 96 zone indicators
- Option for Enable Control keyswitch
- Fully supports Argus Vega protocols
- Network up to 64 panels/repeaters
- 4 programmable sounder circuits as standard
- 5.25 amp power supply to EN54 part 4
- Large graphic display
- In built help and alarm information screens
- Certified to EN54-2/ EN54-4
- Real time clock
- Supports Apollo, Argus Vega and Hochiki loop powered sounders and beacons
- Stylish enclosure design
- Soft-touch tactile buttons
- 2 programmable function buttons
- 3 programmable front panel mounted LED’s
- Improved Front loading Printer (optional)
- Up to 512 programmable inputs/outputs per panel via 2 wire RS485 serial link (optional)
- Simple Windows® graphical configuration utility
- Comprehensive day/night mode facility
- Programmable one touch test mode
- Powerful and versatile cause & effect programming
- Cause & effect wizard including: Cause & effect action, Disablement configuration, Test mode configuration

TECHNICAL SPECIFICATIONS

  • Construction : 1.2mm mild sheet steel
  • Finish : Epoxy powder coated
  • Colour - lid & box : BS 00 A 05 grey - fine texture
  • Colour - controls plate & labels : RAL 7047 light grey - satin
  • Display : 8 lines of 40 characters graphic LCD
  • Detection circuits (Loops) : 2 or 4 (400mA each)
  • Zone LED's : 0, 16, 48 or 96 (up to 500 software zones)
  • 4 sounders circuits : Each fused at 1 Amp (total load 2 Amp)
  • Fire contact : Volt free 1 Amp 30VDC
  • Alarm contact : Volt free 1 Amp 30VDC
  • Fault contact : Volt free 1 Amp 30VDC
  • Programmable relay 1 : Volt free 1 Amp 30VDC
  • Programmable relay 2 : Volt free 1 Amp 30VDC
  • Fire routing output : Monitored-voltage reversing, fused at 500mA
  • Fault routing output : Monitored-voltage reversing, fused at 500mA
  • Extinguisher output : Monitored-voltage reversing, fused at 1A
  • Fault input : Volt free contact input signals fault
  • Reset input : Volt free contact input resets panel
  • Intermittent input : Volt free contact input pulses sounder outputs
  • Continuous input : Volt free contact input for continuous sounders
  • Silence input : Volt free contact input silences sounders
  • Programmable input 1 : Volt free contact for any action required
  • Programmable input 2 : Volt free contact for any action required
  • Programmable input 3 : Volt free contact for any action required
  • Auxiliary 24V DC output : Fused at 500mA
  • System fuse : 5 Amp self-resetting polyfuse
  • Mains fuse : 20mm 3 Amp
  • Operating Temperature : -5 to +50 deg. C
  • Operating humidity : To 95% (non-condensing)
  • Mains voltage supply : 110 or 230V AC 50 or 60 Hz.(specify when ordering, default is 230V)
  • Battery (24 hour standby) : 12Ah 12V (2 per panel) (non-networked)
  • Day/night modes : 2 with variable device sensitivity
  • Input delays : Individual for each device selectable up to 2 minutes
  • Output delays : Individual 2-stage to 10 minutes per stage
  • 2 programmable function buttons : Programmable to carry out any cause & effect, disablement or test action
  • 3 programmable indicators : Red/yellow/green to indicate any action
  • Network (option) : Up to 64 panels on 2 wires (K555 Network Card required)
  • Printer (option) : New front loading feature
  • Download lead : S187 (standard) or X187LS (economy)
  • Dimension - small enclosure : 500 x 355 x 117 mm
  • Dimension - large enclosure : 500 x 460 x 190 mm

 

Nos Services

Ma Commande

Modes de Livraison

Moyens de Paiement

Service après-vente

 

Aide

Rechercher un produit

Nous contacter

Plan du site

Conditions des Offres Promotionnelles

 

 

Ornicom Security products

© 1989 - 2016 Ornicom Tous Droits Réservés.
 
5550 Alle-sur-Semois Belgium
Tel:+32 61 48 01 50
Fax:+32 61 48 01 51
E-mail: Cette adresse e-mail est protégée contre les robots spammeurs. Vous devez activer le JavaScript pour la visualiser.
 
Méthodes de Paiement
SSL