8 Zones 4 Areas Extinguishant Control Panel SIGMA XT+ K21084M4
8 zones 4 areas Extinguishant Fire Control panel SIGMA XT+ Kentec K21084M4
K21084M4 - 8 zones 4 areas Extinguishant Fire Control Panel SIGMA XT+ Kentec
Sigma XT+ control panels are multi-area extinguishant control panels complying with EN12094-1, EN54-2 and EN54-4.
Up to 8 zones of conventional detection with up to 4 extinguishant areas are available.
Stand alone extinguishant control units are also available with 2 monitored inputs to receive initiating signals from remote fire detection control panels or addressable modules.
Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via a simple programming interface.
All extinguishant areas may have up to 7, serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple 4 core cable.
The versatility of the control panel can be enhanced further by the fitting of up to 7 Sigma CP Ancillary boards (K580) or Sigma CP Sounder boards (K461) to the RS485 serial bus. See data sheet DS39 and DS48.
For compatible status units see Sigma Si data sheet DS41.
FEATURES & BENEFITS
- Approved to EN12094-1, EN54-2 and EN54-4
- 2, 4 or 8 detection zones
- 1 to 4 extinguishant areas
- Dual extinguishant outputs for each area (configurable as Main/Reserve)
- First and second stage sounder outputs for each area
- First and second stage volt free changeover contacts for each area
- Released volt free contact per area
- Fault volt free contact per area
- Programmable extinguishant delays
- Programmable output duration
- Extract fan control
- Countdown indicator shows time until release in seconds
- Mode select and manual release controls per area
- Monitored remote manual release input
- Monitored remote Hold input
- Monitored remote Mode select (door interlock) input
- Monitored remote Released pressure switch input
- Monitored remote Low Pressure switch input
- Monitored Abort input
- Serial connection for Sigma Si status units and ancillary boards. (K588)
Recently Viewed
4 Zones 2 Areas Extinguishant Control Panel SIGMA XT+ K21042M3
4 zones 2 areas Extinguishant Fire Control panel SIGMA XT+ Kentec K21042M3
Sounder-Beacon, 32 Tones user selectable, shallow base - AS366 UTC Fire & Security
Transmitter Exd SIL2 Aluminum enclosure LCD SSS4A13
Transmitter Exd SIL2 Aluminum enclosure, 4 entries, copper free, Electronic with1 output RS+4-20mA, LCD display, relay card - Zone 1 areas SMART S-SS SSS4A13 Sensitron
Professional Multi-Gas Monitor GAS-PRO-PID
Professional Multi-Gas Monitor, up to 5 gas GAS-PRO-PID - Crowcon
Smoke Ventilation Button Control Panel 1 line 1 drive group 3A
Smoke ventilation button control panel 1 line 1 drive group 3A Orange metal housing RZN 4503-T D+H
Ultra Fast Integrated UV-IR Flame Detector 40/40D-LB
Ultra Fast Integrated UV/IR Flame Detector Explosion Proof enclosure 40/40D-LB for hydrocarbon-based fuel fires and non-organic fires SharpEye Spectrex
Control Panel kit integrated with GSM/GPRS Transmitter, Keyboard and antenna included CPX200N EBS
Hydrogen Sulphide Gas Detector - Dust Proof Enclosure Version S2168HS
Hydrogen Sulphide Gas Detector, H2S Gas Detector, Sulfane Gas Detector 0-50 ppm 4-20mA - Electrochemical cell - SMART3G-D3 Sensitron Dust Proof Enclosure Version with display Zone 2 category 3 areas S2168HS
I.S. Galvanic barrier specifically designed to drive sounders and beacons for AS372/FA370 series - GBX370 UTC Fire & Security
English (UK)
Français (FR)