Duct detector, single pipe universal FDD710
Duct detector enclosure, single pipe universal, for conventional or analogue addressable detectors - FDD710 UTC Fire & Security
FDD710 - Universal Duct detector enclosure with single pipe for Conventional or Analogue addressable detectors - UTC Fire & Security
The FDD710 single pipe duct detector has been developed to detect smoke in ventilation ducts and combines a smoke detector and an adaptor system where both venturi pipe and housing are specially designed for optimum airflow through the smoke detector. The system fulfils all the requirements for safe fire detection with airflow speeds from 0,2 m/s to 20 m/s.
The FDD710 has been designed to accommodate almost all types of point detectors. Provision is made to fit the required detector base (not provided) into the duct detector.
The unit is easily installed on ventilation ducts.The unique one pipe design ensures correct operation for air inflow and outflow. The unit is supplied standard with a 600mm sampling pipe. The FDD710LP 1.5m extra-long sampling pipe can be used in larger ducts if needed. These pipes can be cut to the correct length if required.
FEATURES & BENEFITS
- One-pipe air sampling system
- Conventional or analogue addressable detectors
- Test hole on cover
- Simple installation
- Sensitive flow indication
- Simple service and maintenance
- Installer-friendly connection of cables
- Foolproof installation of sampling tube
- Specially designed venturi pipe to ensure optimum performance
Recently Viewed
Duct detector, single pipe universal FDD710
Duct detector enclosure, single pipe universal, for conventional or analogue addressable detectors - FDD710 UTC Fire & Security
Analogue High Sensitivity Laser Smoke Detector 7251
Analogue High Sensitivity Laser Smoke Detector 7251 Smoke detector with SYSTEM SENSOR Protocol
Carbon Dioxide Gas Detector SMART3-H LITE S3859CO2
Carbon Dioxide Gas Detector, CO2 Gas Detector 0-5000 ppm - Infrared sensor - SMART3-H LITE for non classified area S3859CO2 Sensitron
Carbon Dioxide Gas Detector - Dust Proof Enclosure Version S2650CO2
Carbon Dioxide Gas Detector, CO2 Gas Detector 0-5% Vol 4-20mA - Infrared sensor - SMART3G-C3 Sensitron Dust Proof Enclosure Version Zone 2 category 3 areas S2650CO2
R32 Gas Detector SMART3-R S4611R32
Difluoromethane Gas Detector, R32 refrigerant Gas Detector, HFC-32 Gas Detector 0-2000 ppm 4-20mA - Infrared sensor - SMART3-R for non classified area S4611R32 Sensitron
Indoor siren, 1 tone - with flash 104 dB AS271 UTC Fire & Security Aritech
SF6 Gas Detector SMART3-R S4613SF6
SF6 Gas Detector, Sulfur hexafluoride Gas Detector 0-2000 ppm 4-20mA - Infrared sensor - SMART3-R for non classified area S4613SF6 Sensitron
Sounder-Beacon, 32 Tones user selectable, deep base - AS367 UTC Fire & Security
Marine Approved Analogue Addressable Manual Call Point HCP-EM
Marine Approved Analogue Addressable Manual Call Point HOCHIKI HCP-E/M(SCI)
Alarmline II Digital LHD Cable 105°C (221°F) w/ PP Sheath AD105P-0500
Digital Linear Heat Detection (LHD) cable 105°C (221°F) with Polypropylene Sheath Alarmline II, 500m - AD105P-0500 - ProReact F1077
English (UK)
Français (FR)