4 Zones Conventional Fire Alarm Panel HRZ4
4 Zones Conventional Fire Alarm Panel HRZ4 Morley-IAS
HRZ4 - 4 Zones Conventional Fire Alarm Panel Morley-IAS
Developed with efficiency in mind, HRZ2-8 zone non intelligent fire alarm panels offer both installers and end users a technically advanced range of functions while remaining easy to install, program and operate. A full range of non-intelligent detectors, advanced non-intelligent detectors, beam detectors, manual call points, duct mounting applications, audible and visible devices are available for use with this panels.
HRZ2-8 series fire alarm panels are ideally suited for facilities including offices, shop units, public houses, B&B, clubs, small industrial units, nursing home and schools, offering a wide range of benefits to installers and end-users.
FEATURES & BENEFITS
- Zones configurable for delay, coincidence, short-circuit alarm, capacitor or resistive end of line
- Fire and fault outputs - volt-free relay or monitored
- Auxiliary power output for ancillary equipment
- 2 configurable inputs for ancillary equipment (e.g. class change, alert, etc.)
- Space for two option modules
- Optional 8-way relay module, common or zonal switching
- Optional 1.5A 4-way sounder module, common or zonal switching
- Battery space for up to 72 hours stand-by
- 2, 4 or 8 zone versions available
TECHNICAL SPECIFICATIONS
- Dimensions (W x H x D) : 356 mm x 318 mm x 96 mm
- Weight : 2 kg (without batteries)
- Supply rating : 230VAC +/- 15%, 50/60Hz, 1.6A
- Auxiliary output voltage : 18.0 - 28.5 VDC
- Auxiliary output current : 0.5A maximum
- Sounder circuit : 0.5A maximum per circuit
- Sounder circuit total : 1.0A maximum
- Operating temperature : -5°C to +45°C
- Non-condensing relative humidity : 5% to 95%
- IP rating : IP30
- Optional sounder module may be used with an external power supply to give an additional 1.5A per module
- Approvals : EN54-13 and Bosec approved CPD number: 0786-CPD-20798
Recently Viewed
BUTANE Gas Detector - Dust Proof Enclosure Version S2096BU
Butane Gas Detector 0-100% LFL 4-20mA - Catalytic sensorl - SMART3G-C3 Sensitron Dust Proof Enclosure Version Zone 2 category 3 areas S2096BU
Additionnal Head Optical Beam Smoke Detector 50m FR5000 NF - 5000-048 - FFE
Alarmline II Digital LHD Cable 88°C (190°F) w/ PP Sheath AD88P-1000
Digital Linear Heat Detection (LHD) cable 88°C (190°F) with Polypropylene Sheath Alarmline II, 1000m - AD88P-1000 - ProReact F1076
R1234YF Gas Detector SMART3-H-FM LITE S4692R1234YF
R-1234yf refrigerant Gas Detector, HFO-1234yf Gas Detector 0-5000 ppm 12-24 Vdc - Infrared sensor - SMART3-H-FM LITE for non classified area S4692R1234YF Sensitron
VOC Gas Detector (Benzene) 0-100 ppm Gas Detector - Dust Proof Enclosure Version S5024BZ
Volatile Organic Compound Detector, VOC Detector 0-100 ppm (Benzene) 4-20mA - PID sensor SMART3G-C3 Sensitron Dust Proof Enclosure Version Zone 2 category 3 areas S5024BZ
Outdoor siren with single amber beacon - polycarbonate cover AS610 UTC Fire & Security Aritech
Complete set 7º OSID smoke detector OSI-10-K
Complete set with 7º OSID smoke detector and wireless transmitter for a distance of 30 to 150 Meter - OSI-10-K - XTRALIS
Standard Mounting Base ECO1000B
ECO1000 Series Standard Mounting Base for Detector ECO1000B System Sensor, Morley-IAS
Analogue Multi-Sensor ACC-EN/SIL
Analogue Multi-Sensor Photoelectric/Heat, Ivory case, SIL2 Approved ACC-EN/SIL Hochiki
IR Flame Detector - Explosion proof enclosure RIV-601P/FA Control Logic
English (UK)