12 zones Esento Marine Fire Alarm Repeater Panel ESEN-R-12MAR
Esento Marine MED Approved 12 Way Fire Alarm Repeater Panel ESEN-R-12MAR - HAES
ESEN-R-12MAR - 12 way Esento Marine Fire Alarm Repeater Panel - HAES
The Esento Marine repeater panel has the same, easy to use, controls and indications as the main control panel but mounted in a smaller cabinet. The repeaters are fully functional with ‘Silence’, ‘Resound’ and ‘Reset’ controls, as well as Disable and Test Mode functions. It is also possible to disable the controls for each or all repeater panels to make them passive (indication only). Up to 8 repeater panels can be supported on a Esento Marine 8-12 zone system.
Repeater panels are designed to be wired in a fault tolerant (fail safe) loop configuration, from comms A to B and back to the main panel again. This enables repeater panels to still work if there is a break in the cables. If replacing an older system where the existing cabling cannot be configured in a loop as above, it is possible to re-programme the panel back to legacy RS485 circuit comms monitoring. This then allows any topology of comms cabling to be utilised.
The main circuit board has 2, switch –ve, inputs which can be used to sound or pulse the alarms. These inputs can also be re-programmed for use as PSU fault inputs. The internal comms PCB has 6, switch –ve, programmable outputs. Different key types are used for the door lock and the ‘activate controls’ key-switch. It is also possible to enable the controls via a 4 digit code entry if preferred. An eight button keypad is used to control the system and allow access to the function options (unless disabled).
The control panel comprises of a sheet steel enclosure suitable for wall mounting with a hinged, lockable front access door. It can be semi recessed, using a suitable recessing bezel. Cable entry is via 20mm ‘knockouts’ located at the top and rear of the cabinet. The battery compartment also includes a secure battery clamp.
The repeaters are supplied with a 1.5 amp internal power supply module. This module complies with the requirements of EN54-4 : 1988 and provides temperature compensated battery management charging.
Esento Marine panels are approved by the BRE which is a Notified Body authorised by the MCA to Modules B & D, Lloyds Register and the American Bureau of Shipping
Available in Grey or Black
FEATURES & BENEFITS
- Same easy-to-use controls and indications as panel
- Can be fully functional or passive
- 12 zonal fire & fault indications
- Integral 1.25 Amp PSU
- Class change & alert inputs
- Test mode and disablement functions
- 6 programmable switch -ve outputs
- Fault tolerant loop or legacy radial wiring options
- 12 month warranty
Recently Viewed
Conventional Fire Panel with User Interface - 4 zone - 1X-F4-xx UTC Fire & Security
2.5 to 30m Microwave Monostatic Sensor FM30(24)-V
2.5 to 30m MicroWave Monostatic Sensor (Volume) 24.15GHz FM30(24)-V - Forteza
Marine Approved Conventional Combined Heat Detector DCD-CE3M
Marine Approved Conventional Combined Rate of Rise & Fixed Temperature Heat Detector (90°C) DCD-CE3M - Hochiki
Cordless Heat Detector Tester Replacement High Capacity Battery Baton SOLO 770 No Climb products
Rechargeable Battery Pack for Solo 365 - SOLO370-1PACK-001 - No Climb products
Alarmline II LHD interconnecting cable AAI-0100
Alarmline II LHD interconnecting cable, 100m - AAI-0100
Ammonia Gas Detector - Dust Proof Enclosure Version S3226AM
(NH3) Ammonia Gas Detector, Azane Gas Detector, Hydrogen nitride Gas Detector 0-100 ppm 4-20mA - Electrochemical cell - SMART3G-D3 Sensitron Dust Proof Enclosure Version with display Zone 2 category 3 areas S3226AM
8 Zones 3 Areas Extinguishant Control Panel SIGMA XT+ K21083M4
8 zones 3 areas Extinguishant Fire Control panel SIGMA XT+ Kentec K21083M4
R449A Gas Detector - Dust Proof Enclosure Version S3922R449A
R-449A refrigerant Gas Detector 0-2000 ppm 4-20mA - Infrared sensor - SMART3G-D3 Sensitron Dust Proof Enclosure Version with display Zone 2 category 3 areas S3922R449A
R454C Gas Detector - Dust Proof Enclosure Version S4826R454C
R454C Gaz Detector 0-100% LFL 4-20mA - Infrared sensor - SMART3G-C3 Sensitron Dust Proof Enclosure Version Zone 2 category 3 areas S4826R454C
English (UK)
Français (FR)