Enclosed Conventional Heat Detector, Weatherproof IP67, 117°C, Class ES - 6298
Enclosed Conventional Heat Detector, Weatherproof IP67, 117°C, Class ES (114 to 130°C) - 6298
6298 - Conventional Weatherproof Heat Detector 117°C Class ES
Heat detectors are normally used in rooms where the temperature can be expected to rise rapidly in case of a fire, or in places where smoke detectors cannot be used. The 6000 series heat detectors are intended for outdoor or indoor use in high humidity areas.
Fixed Temperature Alarm Level
The 6000 series detectors are conventional fixed temperature heat detectors, i.e. they will give an alarm within a response temperature range in accordance with EN54-5:2000. The sensing element is a heat pick-up shield and a bimetal switch. An LED on the detector (not available on the 6298) will light up when the detector activates. All detectors support an output for a remote indicator.
The following types are available (static response temperature, class & EN54-5 temperature range):
• 6295, 57°C, class A2 S (54 to 70°C)
• 6296, 72°C, class B S (69 to 85°C)
• 6297, 87°C, class C S (84 to 100°C)
• 6298, 117°C, class E S (114 to 130°C)
Installation
All electronic componets are mounted in a grey waterproof detector housing and fitted to the supplied connection box. The connection box has three cable inlets. Three compression glands and a silicon gasket for IP67 protection are supplied with the product.
All detectors are provided with three pairs of flying leads with female push-on connectors to connect the zone line cables (in / out) and the remote indicator.
FEATURES & BENEFITS
- Fixed temperature alarm level
- Waterproof (IP67)
Recently Viewed
Enclosed Conventional Heat Detector, Weatherproof IP67, 117°C, Class ES - 6298
Enclosed Conventional Heat Detector, Weatherproof IP67, 117°C, Class ES (114 to 130°C) - 6298
Digital Linear Heat Detection (LHD) cable 68°C (155°F) EN54 approved with PVC Sheath and Stainless Steel Braid PROLINE - TH68ENSS
4 Zones Gas Control Panel Sentox4+
4 Channel, two Alarm thresholds Microprocessor based Gas Control Panel for 4-20mA detectors DIN-rail mounting Sensitron SENTOX 4+ STSX4
Smoke Ventilation Control Panel 2 lines 2 drive groups 4A
Smoke Ventilation Control Panel 2 lines 2 drive groups 4A 24VDC Plastic Housing RZN 4404-M D+H
Sounder-Beacon, 32 Tones user selectable, deep base - AS367 UTC Fire & Security
Alarmline II Digital LHD Cable 88°C (190°F) w/ PVC Sheath AD88-0500
Digital Linear Heat Detection (LHD) cable 88°C (190°F) with PVC Sheath Alarmline II, 500m - AD88-0500 - ProReact F1067
Hexane Gas Detector - Explosion Proof Enclosure Version S2654ES
Hexane Gas Detector 0-100% LFL 4-20mA - Infrared sensor - SMART3G-C2 Sensitron Explosion Proof Enclosure version Zone 1 category 2 areas S2654ES
Green Resettable Call Point + Base RP-GS-01
Green Resettable Call Point with back box RP-GS-01 Vimpex
VOC Gas Detector (Benzene) 0-1000 ppm Gas Detector - Explosion Proof Enclosure Version S5029BZ
Volatile Organic Compound Detector, VOC Detector 0-1000 ppm (Benzene) 4-20mA - PID sensor SMART3G-C2 Sensitron Explosion Proof Enclosure version Zone 1 category 2 areas S5029BZ
Powdered Aerosol Fire Extinguisher GreenEX A200
English (UK)
Français (FR)