Laser Air-sampling Smoke Detector with 1 inlet
Laser Air-sampling Smoke Detector with 1 inlet ICAM by Xtralis
ILS-1 - Laser Air-sampling Smoke Detector with 1 inlet ICAM
The ICAM ILS systems provide Laser Air-sampling Smoke Detection solutions to meet the unique needs of numerous commercial and industrial applications. ILS systems are suitable for both medium sensitivity and multihole Class C applications.
How it Works
The ILS systems actively draw air from the protected area through sampling holes in a pipe network. Sampled air is then filtered before being analyzed by medium sensitivity laser spot (point) detectors incorporated in the systems.
Alarm states (Alert, Action or Fire) are reported by activating functional LEDs in the display and dry contact relays.
The systems utilize a high performance aspirator and software configurable flow monitoring circuitry. Air flow is displayed on a ten element bar graph that can be adjusted for high and low flow thresholds, and flow failure is reported as a device fault via dedicated fault relays.
Programming & Diagnostics
The sensitivity thresholds for each of the three alarm levels, fan speed and flow sensitivity can be individually programmed. A USB interface provides a connection to a PC for system configuration. The ILS system can also be locally configured through an integrated programming interface.
FEATURES & BENEFITS
- Single channel smoke detection
- Laser air-sampling smoke detection
- Multiple detection strategies
- 100 m (328 ft) per sampling pipe
- Microprocessor controlled and programmed
- Highest fan capacity in its class
- Integral display and programmer
- Field serviceable air filter
- Adjustable aspirator speed with airflow monitoring
- IP65 enclosure
DETECTION STRATEGIES
The ILS-1 can be fitted with one or two detectors per system.
ILS-1 systems fitted with one spot (point) detector is capable of providing single area detection, but ILS-1 fitted with two detectors can be configured for a number of detection strategies.
Possible detection strategies for ILS systems fitted with two spot (point) detectors :
- Redundancy (OR) *
- Coincident / Double-Knock (AND) *
* These are software programmable modes for an ILS-1 system fitted with two detectors.
* Subject to local codes and standards.
Note: (OR / AND) represents the boolean logic for combining two detectors to achieve detection strategy.
LISTINGS/APPROVALS
Equipment Approvals:
- EN54-20 (VdS)
- CE EMC
- CPD
- EN54-20 Sensitivity (holes per pipe)
- Class A - 3 holes
- Class B - 6 holes
- Class C - 18 holes
Factory Approvals:
- VdS
TECHNICAL SPECIFICATIONS
- Integrated detectors : 1 laser spot (point) detector
- Supply Voltage : 24 VDC nominal (18 to 30 VDC)
- Current : 300 mA (max)
- Dimensions (WHD) : 259 mm x 184 mm x 166 mm (10.2 in. x 7.2 in. x 6.5 in.)
- Operating Conditions : Temperature: -10 to 50 °C (14 to 122 ©F)
- Humidity : 10 to 95% RH (noncondensing)
- Inlet Pipe Size : Outer Diameter: 25 mm (1 in.), Inner Diameter: 21 mm (0.8 in.)
- Sampling Network : Pipe Length: 100 m (328 ft.) per inlet
- Sensitivity : 0.06 to 6.0 % obs/m (0.02 to 1.83 % obs/ft)
- IP Rating : IP65
- Filtration : Serviceable filter, External filter optional
- Flow Monitoring and Reporting : High and Low adjustable
- Fan Control : 10 programmable speeds
- Relays : Contacts rated at 1A @ 30 VDC, NO/NC
- 3 relays : Action, Fire, Fault
- Cable Termination Power Supply : 18 AWG min. (16 x 0.25 mm dia.)
- Cable Termination Field Connections : 11 AWG max. (2.5 mm dia.)
- USB : Standard USB cable for Type B USB connector
-
Recently Viewed
Laser Air-sampling Smoke Detector with 1 inlet
Laser Air-sampling Smoke Detector with 1 inlet ICAM by Xtralis
Propane Gas Detector - Dust Proof Enclosure Version S2156PR
Propane Gas Detector, n-propane Gas detector 0-100% LFL 4-20mA - Catalytic sensor - SMART3G-D3 Sensitron Dust Proof Enclosure Version with display Zone 2 category 3 areas S2156PR
Powdered Aerosol Fire Extinguisher GreenEX A5000
IR Flame Detector - watertight case with IP66 grade protection RIV-601P/F Control Logic
Fire sounder-beacon, high output, outdoor AS371
Fire sounder-beacon, High sound output, xenon beacon, outdoor - AS371 UTC Fire & Security
Halogen Free Twisted & Shielded Fire Resistant Cable with two wires of 1.5mm2 available in 500m - Moreley-IAS - Honeywell
VOC Gas Detector (Benzene) 0-100 ppm Gas Detector - Explosion Proof Enclosure Version S5025BZ-LD
Volatile Organic Compound Detector, VOC Detector Benzene 0-100 ppm 4-20mA - PID sensor SMART3G-C2-LD Sensitron Explosion Proof Enclosure with LED version Zone 1 category 2 areas S5025BZ-LD
10-75m Microwave Bistatic Sensor FORTEZA-FONAR
10-75m Microwave Bistatic Masked Sensor 9.375GHz in decorative lamp FORTEZA-FONAR - Forteza
2 Analogue Loops 16 Zones with APOLLO Protocol Addressable Fire Control Panel Large Enclosure + Key & Printer Kentec SYNCRO AS A80162M3P
Sounder-Beacon, 32 Tones user selectable, deep base - AS367 UTC Fire & Security
English (UK)
Français (FR)