Laser Air-sampling Smoke Detector with 1 inlet
Laser Air-sampling Smoke Detector with 1 inlet ICAM by Xtralis
ILS-1 - Laser Air-sampling Smoke Detector with 1 inlet ICAM
The ICAM ILS systems provide Laser Air-sampling Smoke Detection solutions to meet the unique needs of numerous commercial and industrial applications. ILS systems are suitable for both medium sensitivity and multihole Class C applications.
How it Works
The ILS systems actively draw air from the protected area through sampling holes in a pipe network. Sampled air is then filtered before being analyzed by medium sensitivity laser spot (point) detectors incorporated in the systems.
Alarm states (Alert, Action or Fire) are reported by activating functional LEDs in the display and dry contact relays.
The systems utilize a high performance aspirator and software configurable flow monitoring circuitry. Air flow is displayed on a ten element bar graph that can be adjusted for high and low flow thresholds, and flow failure is reported as a device fault via dedicated fault relays.
Programming & Diagnostics
The sensitivity thresholds for each of the three alarm levels, fan speed and flow sensitivity can be individually programmed. A USB interface provides a connection to a PC for system configuration. The ILS system can also be locally configured through an integrated programming interface.
FEATURES & BENEFITS
- Single channel smoke detection
- Laser air-sampling smoke detection
- Multiple detection strategies
- 100 m (328 ft) per sampling pipe
- Microprocessor controlled and programmed
- Highest fan capacity in its class
- Integral display and programmer
- Field serviceable air filter
- Adjustable aspirator speed with airflow monitoring
- IP65 enclosure
DETECTION STRATEGIES
The ILS-1 can be fitted with one or two detectors per system.
ILS-1 systems fitted with one spot (point) detector is capable of providing single area detection, but ILS-1 fitted with two detectors can be configured for a number of detection strategies.
Possible detection strategies for ILS systems fitted with two spot (point) detectors :
- Redundancy (OR) *
- Coincident / Double-Knock (AND) *
* These are software programmable modes for an ILS-1 system fitted with two detectors.
* Subject to local codes and standards.
Note: (OR / AND) represents the boolean logic for combining two detectors to achieve detection strategy.
LISTINGS/APPROVALS
Equipment Approvals:
- EN54-20 (VdS)
- CE EMC
- CPD
- EN54-20 Sensitivity (holes per pipe)
- Class A - 3 holes
- Class B - 6 holes
- Class C - 18 holes
Factory Approvals:
- VdS
TECHNICAL SPECIFICATIONS
- Integrated detectors : 1 laser spot (point) detector
- Supply Voltage : 24 VDC nominal (18 to 30 VDC)
- Current : 300 mA (max)
- Dimensions (WHD) : 259 mm x 184 mm x 166 mm (10.2 in. x 7.2 in. x 6.5 in.)
- Operating Conditions : Temperature: -10 to 50 °C (14 to 122 ©F)
- Humidity : 10 to 95% RH (noncondensing)
- Inlet Pipe Size : Outer Diameter: 25 mm (1 in.), Inner Diameter: 21 mm (0.8 in.)
- Sampling Network : Pipe Length: 100 m (328 ft.) per inlet
- Sensitivity : 0.06 to 6.0 % obs/m (0.02 to 1.83 % obs/ft)
- IP Rating : IP65
- Filtration : Serviceable filter, External filter optional
- Flow Monitoring and Reporting : High and Low adjustable
- Fan Control : 10 programmable speeds
- Relays : Contacts rated at 1A @ 30 VDC, NO/NC
- 3 relays : Action, Fire, Fault
- Cable Termination Power Supply : 18 AWG min. (16 x 0.25 mm dia.)
- Cable Termination Field Connections : 11 AWG max. (2.5 mm dia.)
- USB : Standard USB cable for Type B USB connector
-
Recently Viewed
Iso Pentane Gas Detector - Explosion Proof Enclosure Version S2097IN
Iso Pentane Gas Detector, Methylbutane Gas Detector 0-100% LFL 4-20mA - Catalytic sensor - SMART3G-C2 Sensitron Explosion Proof Enclosure version Zone 1 category 2 areas S2097IN
Plug-In Detector Base with 470R B401R
Plug-In Detector Base with 470R current limited Resistor for System Sensor Conventional Detectors, Morley-IAS B401R
Hydrogen Sulphide Gas Detector - Dust Proof Enclosure Version S2168HS
Hydrogen Sulphide Gas Detector, H2S Gas Detector, Sulfane Gas Detector 0-50 ppm 4-20mA - Electrochemical cell - SMART3G-D3 Sensitron Dust Proof Enclosure Version with display Zone 2 category 3 areas S2168HS
Monitoring Alarm Station Receiver Enigma II
Monitoring Alarm Station Receiver (base unit) without Line Cards Enigma II - ASC Global
Extinguishant Fire Detection Panel S2.6A SIGMA ZXT
Single Area, 3 conventional detection zones Extinguishant Fire Detection panel, standard enclosure, 2.6A power supply SIGMA ZXT Kentec K192311XM2
8 Zones 4 Areas Extinguishant Control Panel SIGMA XT+ K21084M4
8 zones 4 areas Extinguishant Fire Control panel SIGMA XT+ Kentec K21084M4
Carbon Dioxide Gas Detector - Explosion Proof Version S2652CO2
Carbon Dioxide Gas Detector, CO2 Gas Detector 0-5% Vol 4-20mA - Infrared sensor - SMART3G-C2 Sensitron Explosion Proof Enclosure version Zone 1 category 2 areas S2652CO2
Methane Gas Detector - Explosion Proof Enclosure Version S2155ME-LD
Methane Gas Detector, CH4 Gas Detector, Natural Gas Detector 0-100% LFL 4-20mA - Catalytic sensor - SMART3G-C2-LD Sensitron Explosion Proof Enclosure with LED version Zone 1 category 2 areas S2155ME-LD
Sulphur Dioxide Gas Detector - Explosion Proof Enclosure Version S3005SD
(SO2) Sulphur Dioxide Gas Detector, Sulfur dioxide Gas Detector, Sulfurous anhydride Gas Detector 0-20 ppm 4-20mA - Intrinsically Safe Electrochemical Cell - SMART3G-D2 Sensitron Explosion Proof Enclosure Version with LCD display Zone 1 category 2 areas S3005SD
Nitrogen Dioxide Gas Detector - Explosion Proof Version S3008ND
Nitrogen Dioxide Gas Detector, NO2 Gas Detector 0-20 ppm 4-20mA - Intrinsically Electrochemical cell - SMART3G-C2 Sensitron Explosion Proof Enclosure version Zone 1 category 2 areas S3008ND
English (UK)
Français (FR)