UL-FM 2 zone Conventional Control Panel K1842
UL/FM 2 zone Conventional Fire Alarm Control Panel Sigma A-CP K1842 Kentec
K1842 - UL/FM 2 zone Conventional Fire Alarm Control Panel Sigma A-CP - Kentec
K1842-11 - 2 Conventional zones - Red cabinet
K1842-41 - 2 Conventional zones - Grey cabinet
K1852-11 - 2 Conventional zones with dialer - Red cabinet
K1852-41 - 2 Conventional zones with dialer - Grey cabinet
The Sigma A-CP range of conventional fire control panels with optional built in communicator are available with 2, 4 or 8 initiating circuits which may be extensively configured via a simple front panel operated programming method.
The low standby power requirements and cost effective small batteries allow the panel to be mounted in a small discrete enclosure which is available in standard red or optionally in an attractive grey colour.
A simple programming method using just 3 front panel buttons allows an extensive list of configuration options to be set and reviewed.
Single board construction which allows easy removal of all electronic parts by removing just 2 screws and ample provision of cable entry knockouts simplify installation.
4 Amp notification appliance power and built in selectable sync protocols provide ample power and control for a wide range of standard notification appliances.
The built in RS485 communications bus provides the facility to connect 4 wire annunciators or ancillary relay boards to provide further indication and control options throughout a premises.
The optional DACT allows dual line reporting to central stations and provides a 500 event history buffer.
FEATURES & BENEFITS
- UL864 approved
- Two, four or eight initiating circuits
- Initiating circuits individually configurable as Fire, Water flow or Supervisory
- Two 2A notification appliance circuits
- Selectable NAC sync protocols
- Two 2.0A notification appliance circuits
- 6.5A power supply
- Alarm verification selectable by zone
- Resettable Aux power output rated at 0.3A
- Aux power configurable to power off on Fire condition
- Fire, Trouble and Supervisory relays
- Single person walk test function
- Optional DACT
- Many advanced configuration options
- 72 hour standby with 7Ah batteries
- Compact enclosure
- Fire Drill capability
Recently Viewed
Fireray 5000 System Controller only FR5000-003
FR5000 System Controller only UL/FM - 5000-003 - FFE
Dimethyl Ether Gas Detector - Explosion Proof Enclosure Version S2654DT-LD
Dimethyl Ether Gas Detector, Methoxymethane Gas Detector 0-100% LFL 4-20mA - Infrared sensor - SMART3G-C2-LD Sensitron Explosion Proof Enclosure with LED version Zone 1 category 2 areas S2654DT-LD
Ammonia Gas Detector - Explosion Proof Version S2135AM-LD
(NH3) Ammonia Gas Detector, Azane Gas Detector, Hydrogen nitride Gas Detector 0-1000 ppm 4-20mA - Electrochemical cell - SMART3G-C2-LD Sensitron Explosion Proof Enclosure with LED version Zone 1 category 2 areas S2135AM-LD
UV Flame Detector 40-40U
UV Flame Detector Explosion Proof enclosure 40/40U SharpEye Spectrex
Ammonia Gas Detector - Explosion Proof Version S2133AM-LD
(NH3) Ammonia Gas Detector, Azane Gas Detector, Hydrogen nitride Gas Detector 0-200 ppm 4-20mA - Electrochemical cell - SMART3G-C2-LD Sensitron Explosion Proof Enclosure with LED version Zone 1 category 2 areas S2133AM-LD
Oxygen Detector - Explosion Proof Enclosure Version S3911O2
Oxygen Detector, O2 Detector 0-25% Vol 4-20mA - Electrochemical Cell - SMART3G-G1 Sensitron Explosion Proof Enclosure with Display Group 1 M2 areas S3911O2
English (UK)
Français (FR)