Fire Exit Photoluminescent Safety Sign 23321
Fire Exit Photoluminescent Safety Sign 23321 150 x 150 mm
SIN23321 - 'Emergency Exit' Photoluminescent Safety Sign 150 x 150 mm
It is necessary to make sure that from any given point within a building, people have clear directional guidance on how to reach a place safety. These instructions are given by using standard evacuation signs along the evacuation route.
The evacuation safety system is comprised of signs positioned above doors and signs indicating all changes of direction along an evacuation route. It is essential that when reaching a sign people can already see the next one and continue that way until the final exit.
All escape route signs should be installed between 1.8m and 2.5m from floor level to the base of the sign.
For the correct functioning of signs, they must be mounted according to the appropriate viewing angle.
Type 1 (Single-Sided) : Parallel wall mounting sign.
The best photoluminescent properties are achieved if the signs are installed as close to the light sources as possible, preferably receiving direct light. This guarantees that signs remain visible in the absence of light.
SPECIFICATIONS TECHNIQUES
- Material : Photoluminescent rigid plastic 2mm thickness
- Printing : Serigraphy, high quality gloss paint with UV resistance and a 5-year guarantee
- Fire Resistance : Class M1
- Surface : Antistatic and easy to clean
- chemical Characteristics : Non-radioactive, non-phosphorous, lead-free and non-toxic
- Luminance intensity after 10 min : 215 mcd/m2
- Luminance intensity after 60 min : 30 mcd/m2
-
Recently Viewed
Fire Exit Photoluminescent Safety Sign 23002
Fire Exit Photoluminescent Safety Sign 23002 200 x 100 mm
Transmitter Exd SIL2 Stainless Steel enclosure LCD SSS2S17
Transmitter Exd SIL2 Stainless Steel enclosure, 4 entries, Electronic with1 output RS+4-20mA, LCD display, relay card, Hart modem - Zone 1 areas SMART S-SS SSS2S17 Sensitron
Alarmline II Digital LHD Cable 185°C (365°F) w/ PVC Stainless Steel Sheath AD185SS-0500
Digital Linear Heat Detection (LHD) cable 185°C (365°F) with PVC and Stainless Steel Sheath Alarmline II, 500m - AD185SS-0500 - ProReact F1082
Electronic Smoke Detector Test Kit & Removal Kit 9.3 Metres SOLO900
A test kit with the Electronic Smoke detector tester SOLO365, Removal Tool and Access pole for testing detector at heights up to 9.3 metres - SOLO 900 - No Climb
Powdered Aerosol Fire Extinguisher GreenEX A50
Ethylene Oxide portable gas monitor Gasman-ETO
Portable Ethylene Oxide Gas Detector (ETO), 1,2-Epoxyethane, Dimethylene Oxide, Oxacyclopropane, Oxiranne 0-10 ppm Gasman ETO - Crowcon
A simple kit with the Electronic Smoke detector tester SOLO365 including access pole for testing detector at heights up to 6 metres - SOLO 909 - No Climb
4 Zones Conventional Fire Alarm Panel HRZ4 Morley-IAS
Portable Oxygen Detector, O2 Detector 0-30% Vol ClipSens O2 - Sensotran
Tie Wrap (Pack of 25) - Stainless Steel - A1177-025
English (UK)