Marine Approved Analogue Addressable Manual Call Point HCP-EM
Marine Approved Analogue Addressable Manual Call Point HOCHIKI HCP-E/M(SCI)
HCP-E/M(SCI) - Marine Approved Analogue Addressable Manual Call Point - HOCHIKI
Model HCP-EM is a Marine Approved Manual Call Point, which is fully compatible with Hochiki’s ESP analogue addressable protocol.
The HCP-EM incorporates a red LED mounted on the front cover, which can be selected as pulsing/non-pulsing for communications polling and is continuously lit when the unit is operated. The HCP-EM is operated by pressing the EN54 compliant non-frangible (plastic) element and, once operated, produces a high level ESP interrupt, allowing the control panel to respond very quickly. A built in test function initiated by the control panel ensures the integrity of the device at all times and the device can be tested by insertion of a test key in the underside of the unit. Two terminal blocks are provided for easy connection to the loop wiring.
The unit is addressed using the TCH-B100 Hand Held Programmer for quick and reliable addressing. The unit can be flush mounted as supplied. For surface fixing a suitable back box such as the SR MOUNTING BOX is required (sold separately).An optional glass element is also available.
FEATURES & BENEFITS
- Fast response
- Status LED
- Non-frangible element fitted as standard (conforms to EN54)
- Addressed with TCH-B100 Hand Held Programmer
- Surface or flush mounting (if surface mounting, requires SR MOUNTING BOX – sold separately)
- Approved to MED by GL
- GL Type approval
- Approved by LPCB
Recently Viewed
Voyage Data Recorder Output Card OPCARD-8
Voyage Data Recorder Output Card for Esento Marine control panel OPCARD-8 - HAES
4 Loops, Networkable, Analogue Addressable Fire Alarm Control Panel DXc4 Morley-IAS
Propylene Gas Detector - Explosion Proof Enclosure Version S2654PP-LD
Propylene Gas Detector, Propene Gas Detector, Methylethylene Gas Detector 0-100% LFL 4-20mA - Infrared sensor - SMART3G-C2-LD Sensitron Explosion Proof Enclosure with LED version Zone 1 category 2 areas S2654PP-LD
Propane Gas Detector - Explosion Proof Enclosure Version S2097PR
Propane Gas Detector 0-100% LFL 4-20mA - Catalytic sensor - SMART3G-C2 Sensitron Explosion Proof Enclosure version Zone 1 category 2 areas S2097PR
Ethane Gas Detector - Explosion Proof Enclosure Version S2654EN
Ethane Gas Detector, C2H6 Gas Detector 0-100% LFL 4-20mA - Infrared sensor - SMART3G-C2 Sensitron Explosion Proof Enclosure version Zone 1 category 2 areas S2654EN
R449A Gas Detector - Dust Proof Enclosure Version S3921R449A
R-449A refrigerant Gas Detector 0-2000 ppm 4-20mA - Infrared sensor - SMART3G-C3 Sensitron Dust Proof Enclosure Version Zone 2 category 3 areas S3921R449A
English (UK)
Français (FR)



