ZI-02EN Control Unit
ZI-02EN EN54 Dual Zone Distance Locator for Digital Heat Linear Detector (LHD)
ZI-02EN - Dual Zone Distance Locator EN54 - Proline
The Proline ZI-02EN is a dual zone module for monitoring up to two zones of Proline Digital Linear Heat Detection Cable.
If an overheat or fire situation triggers either zone of the Digital LHD cable, the unit automatically calculates and displays the distance along the cable, in feet and metres, to the alarm point.
The two zones can operate independently of each other, or in interlock mode and a separate alarm and normally conducting fault output are provided for each zone.
The unit is intended to be installed between the Digital Linear Heat Detection Cable and a conventional or addressable fire alarm control panel. It has power, fault and alarm indication, as well as volt free outputs for fault and alarm, corresponding to each zone.
The Proline ZI-02EN can be used with Digital Fixed Temperature Linear Heat Detection Cable, which is to be installed in hazardous areas using intrinsically safe barriers. The ZI-02EN unit should be installed in the safe area and the intrinsically safe barrier used to separate the safe area and the hazardous area.
It may also be connected to an industrial process control system using the two wire RS-485 Modbus RTU/ASCII output.
FEATURES & BENEFITS
- EN54-28:2106 approved File No S36857
- Can monitor 2 Zones of Proline EN digital cables
- Independent or Interlock/Coincidencedetection
- Accurate alarm point displayed in metres
- RS-485 Communication
- CE UKCA Marked
Recently Viewed
Butane Gas Detector - Dust Proof Enclosure Version S2156BU
Butane Gas Detector 0-100% LFL 4-20mA - Catalytic sensor - SMART3G-D3 Sensitron Dust Proof Enclosure Version with display Zone 2 category 3 areas S2156BU
8 Zones 2 Areas Extinguishant Control Panel SIGMA XT+ K21082M3
8 zones 2 areas Extinguishant Fire Control panel SIGMA XT+ Kentec K21082M3
Marine Approved Analogue Addressable Manual Call Point HCP-EM
Marine Approved Analogue Addressable Manual Call Point HOCHIKI HCP-E/M(SCI)
Extinguishant Fire Detection Panel L5.0A SIGMA ZXT
Single Area, 3 conventional detection zones Extinguishant Fire Detection panel, large enclosure, 5.0A power supply SIGMA ZXT Kentec K195311XM3
Complete set 7º OSID smoke detector OSI-10-K
Complete set with 7º OSID smoke detector and wireless transmitter for a distance of 30 to 150 Meter - OSI-10-K - XTRALIS
Oxygen portable monitor Clip SGD CL-O-19
Portable Oxygen Detector, O2 Detector 0-30% Vol. Clip SGD CL-O-19 - Crowcon
8 Zones 4 Areas Extinguishant Control Panel SIGMA XT+ K21084M4
8 zones 4 areas Extinguishant Fire Control panel SIGMA XT+ Kentec K21084M4
Benzene Gas Detector - Explosion Proof Enclosure Version S2155BZ
Benzene Gas Detector, Benzol Gas Detector, Phene Gas Detector 0-100% LFL 4-20mA - Catalytic sensor - SMART3G-C2 Sensitron Explosion Proof Enclosure version Zone 1 category 2 areas S2155BZ
Oxygen Gas Detector - Dust Proof Enclosure Version S2642O2
Oxygen Detector, O2 Gas Detector 0-25% Vol 4-20mA - Electrochemical cell - SMART3G-D3 Sensitron Dust Proof Enclosure Version with display Zone 2 category 3 areas S2642O2
Oxygen portable monitor Clip SGD CL-O-19.5
Portable Oxygen Detector, O2 Detector 0-30% Vol. Clip SGD CL-O-19.5 - Crowcon
English (UK)
Français (FR)