Oxygen Detector, O2 Detector 0-25% Vol 4-20mA - Electrochemical cell - SMART3-R for non classified area S4593O2 Sensitron
S4593O2 - OXYGEN Detector (O2) 0-25% Vol, 4-20mA - Electrochemical cell - SMART3-R
S4593O2 SMART3-R gas detectors are employed to detect Oxygen, O2 Oxygen contents for both it depletion and enrichment (%Vol) in non classified areas.
The SMART3-R have been designed for non classified areas and are ideal for the detection of flammable, toxic and refrigerant gasses in non hazardous environments.
The detectors provide analog 4-20 mA, digital RS485 transmissions and 3-relay outputs.
A multi-colour LED light ring offers a visual indication of the detector' status while an internal buzzer activates to warn of any fault or alarm condition.
SMART3-R are rated to IP42 and feature one-man calibration via the STS/CKD series calibration keypad.
On request, SMART3-R can be supplied with remote sensor head. The detector will be supplied complete with 5m RJ12 6P6C cable.
SMART3R comply with the following new standards:
• EN 378-3
• EN14624
• EN 50676
• IEC 60335-2-40 Annex LL
• ISO 5149-3
• F-Gas Regulation
FEATURES & BENEFITS
• Standard 4-20 mA, RS485 and 3-relay outputs
• Multicolour LED ring
• Internal buzzer for audible warning
• Ongoing system self-diagnosis
• Wide range of sensors and detectable gases
• Optional remote sensor head
• Easy sensor replacement
• Standard 12-24 Vdc power supply. On request 90-240 Vac, without 4-20 mA transmission
Gas Detector type : Oxygen Gas detector, O2 Gas detector
Recently Viewed
R404A Gas Detector SMART3-R S4640R404A
R404A Gas Detector 0-5000 ppm 4-20mA - Infrared sensor - SMART3-R for non classified area S4640R404A Sensitron
Sealed Lead Acid 12V 12AH Yuasa Yucel NP12-12
Intrinsically Safe Conventional Photoelectric Smoke Detector SLR-E-IS/SIL
Intrinsically Safe Conventional Photoelectric Smoke Detector, SIL2 approved SLR-E-IS/SIL - Hochiki
Miniature Line Simulator GSM 4G transmitter EasyLine 4G - ASC Global
Fire sounder, 32 Tones user selectable, shallow base, white - AS363W UTC Fire & Security
Analogue Common Mounting Base YBN-R-3/SIL
Analogue Common Mounting Base, Ivory, SIL2 approved YBN-R/3/SIL HOCHIKI
Marine Approved Conventional Manual Call Point Red MCP1A
Marine Approved Conventional Manual Call Point Red MCP1A - Hochiki
Oxygen Gas Detector - Explosion Proof Version S2641O2-LD
Oxygen Detector, O2 Detector 0-25% Vol 4-20mA - Electrochemical cell - SMART3G-C2-LD Sensitron Explosion Proof Enclosure with LED version Zone 1 category 2 areas S2641O2-LD
Isobutylene Gas Detector - Explosion Proof Enclosure Version S2654IL-LD
Isobutylene Gas Detector, 2-methylpropene Gas Detector 0-100% LFL 4-20mA - Infrared sensor - SMART3G-C2-LD Sensitron Explosion Proof Enclosure with LED version Zone 1 category 2 areas S2654IL-LD
4 Loops Analogue Addressable Taktis Fire Control Panel
The next generation of 4 Loops Addressable Analogue Taktis Fire Control Panel - TAAE4 - Kentec
English (UK)
Français (FR)