Flame Simulator for Single IR FS1300
Flame Simulator to test all Spectrex Single IR Flame detector - FS-1300 Spectrex
FS-1300 - Flame Simulator for all Single IR Flame detector - Spectrex
Providing foolproof, full loop testing of your flame detection system in Zones 1 and 2 hazardous areas at up to 4ft (1.2m) testing distance
To be fully secure against fire, flame detector self-testing is not enough. According to most local jurisdictional authorities and as required for SIL2 compliance, you need to test and ensure the integrity of your entire flame detection system at least once per year. That means performing a full system loop test from the detector, through the wiring to the controller, and up to the actual alarm notification. The only way to do so, without lighting a real fire, is with an external flame simulator.
The FS-1300 FLAME SIMULATOR is the essential complimentary tool to the self-testing capabilities of your Sharpeye™ Single IR Flame Detectors. It brings fire prevention safety to a higher level by giving you the ability to fully test the operational readiness of your entire fire detection system:
• Test the integrity of all the system components: all alarm outputs, all cabling and connections and the fire alarm panel functionality.
• Test clear line of sight: By using the Spectrex Flame Simulator, you will ensure that no object is obstructing the field of view, and that the detector’s window lens is not obscured.
Therefore, by simulating a fire that actually triggers the detector outputs, the model FS-1300 verifies the correct operation of the Single IR flame detector, performs an essential end-to-end loop test and verifies window cleanliness.
The robust and reliable FS-1300 FLAME SIMULATOR allows remote testing of flame detectors, which are often located in difficult to access and/or classified hazardous areas (Zones 1 and 2).
Replacing the old model 20/20-312
FEATURES & BENEFITS
- Long-range flame detector activation – at a range up to 10ft (3m) – a 33% increase compared to previous simulator models.
- Reduced maintenance costs with easy access for testing detectors, in hard to reach places, from floor/deck level without the need for scaffolding or ladders
- Highly portable – for hand held operation by a single operator
- Easy aiming using laser diode
- ATEX/IECEx approved for use in Zones 1 and 2 hazardous areas
- Single charge is sufficient to test up to 100 detectors
Other reference : 380114-3
Recently Viewed
Indoor siren, 1 tone - without flash AS270 UTC Fire & Security Aritech
1.3MP HD Network Speed Dome DS-2DE5174
1.3MP HD Network Speed Dome DS-2DE5174 series - HIKVISION
Scorpion Point Detector Head Unit Kit SCORP1001-001 No Climb products
2MP HD Network Speed Dome DS-2DE5186
2MP HD Network Speed Dome DS-2DE5186 series - HIKVISION
2 Zones Conventional Fire Alarm Panel HRZ2 Morley-IAS
Carbon Dioxide Gas Detector - Explosion Proof Enclosure Version S2634CO2
Carbon Dioxide Gas Detector, CO2 Gas Detector 0-2% Vol 4-20mA - Infrared sensor SMART3G-D2 Sensitron Explosion Proof Enclosure Version with display Zone 1 Category 2 areas S2634CO2
Ethane Gas Detector - Explosion Proof Enclosure Version S2157EN
Ethane Gas Detector, C2H6 Gas Detector 0-100% LFL 4-20mA - Catalytic sensor - SMART3G-D2 Sensitron Explosion Proof Enclosure Version with display Zone 1 category 2 areas S2157EN
8 inch Fire bell for outdoor use, EN54-3 Approved, 24 VDC - AB380E UTC Fire & Security
Home Systems Audio Board with X-10 CS534 UTC Fire & Security Aritech
English (UK)
Français (FR)




