Duct detector, single pipe universal FDD710
Duct detector enclosure, single pipe universal, for conventional or analogue addressable detectors - FDD710 UTC Fire & Security
FDD710 - Universal Duct detector enclosure with single pipe for Conventional or Analogue addressable detectors - UTC Fire & Security
The FDD710 single pipe duct detector has been developed to detect smoke in ventilation ducts and combines a smoke detector and an adaptor system where both venturi pipe and housing are specially designed for optimum airflow through the smoke detector. The system fulfils all the requirements for safe fire detection with airflow speeds from 0,2 m/s to 20 m/s.
The FDD710 has been designed to accommodate almost all types of point detectors. Provision is made to fit the required detector base (not provided) into the duct detector.
The unit is easily installed on ventilation ducts.The unique one pipe design ensures correct operation for air inflow and outflow. The unit is supplied standard with a 600mm sampling pipe. The FDD710LP 1.5m extra-long sampling pipe can be used in larger ducts if needed. These pipes can be cut to the correct length if required.
FEATURES & BENEFITS
- One-pipe air sampling system
- Conventional or analogue addressable detectors
- Test hole on cover
- Simple installation
- Sensitive flow indication
- Simple service and maintenance
- Installer-friendly connection of cables
- Foolproof installation of sampling tube
- Specially designed venturi pipe to ensure optimum performance
Recently Viewed
Duct Detector Housing with Standard Base
Duct Adapter for detector Aurora, Vega or Sagittarius Argus Security
Marine Approved Analogue Dual Input Module CHQ-DIM2/M(SCI)
Marine Approved Analogue Dual Input Module with Isolator HOCHIKI CHQ-DIM2/M(SCI)
Linear Heat Detection System - Control Unit LWM1
Linear Heat Detection System - Alarmline Control Unit LWM1 - Kidde 22-11810-050
Open Path Gas Detector SafEye Quasar 904
The SafEye Quasar 900 Series is the very latest open path IR technology and detects a wide range of hydrocarbon gases – including alkanes (methane to hexane) and ethylene. Quasar 904
Short-Circuit Isolator Base YBN-R/3(SCI)/SIL
Short-Circuit Isolator Base, Ivory, SIL2 approved YBN-R/3(SCI)/SIL Hochiki
Nitrogen Dioxide Gas Detector - Explosion Proof Enclosure Version S3009ND
Nitrogen Dioxide Gas Detector, NO2 Gas Detector 0-20 ppm 4-20mA - Intrinsically Safe Electrochemical Cell - SMART3G-D2 Sensitron Explosion Proof Enclosure Version with LCD display Zone 1 category 2 areas S3009ND
Chlorine Gas Detector - Explosion Proof Enclosure Version S3015CL
Chlorine Gas Detector, CL2 Gas Detector 0-20 ppm 4-20mA - Intrinsically Safe Electrochemical Cell - SMART3G-D2 Sensitron Explosion Proof Enclosure Version with LCD display Zone 1 category 2 areas S3015CL
CMS Automation Software Package Alarm Sys
CMS Automation Software Package Alarm Sys - ASC Global
Digital 58°C Thermal Detector with Isolator MIFHSES2I
Digital 58°C Thermal Detector with Isolator - Pure White - MI-FHSE-S2I Morley-IAS
Toluene Gas Detector - Explosion Proof Enclosure Version S2155TO-LD
Methylbenzene Gas Detector, Phenylmethane Gas Detector, Toluene Gas Detector 0-100% LFL 4-20mA - Catalytic sensor - SMART3G-C2-LD Sensitron Explosion Proof Enclosure with LED version Zone 1 category 2 areas S2155TO-LD