UL-FM 2 zone Conventional Control Panel K1842
UL/FM 2 zone Conventional Fire Alarm Control Panel Sigma A-CP K1842 Kentec
K1842 - UL/FM 2 zone Conventional Fire Alarm Control Panel Sigma A-CP - Kentec
K1842-11 - 2 Conventional zones - Red cabinet
K1842-41 - 2 Conventional zones - Grey cabinet
K1852-11 - 2 Conventional zones with dialer - Red cabinet
K1852-41 - 2 Conventional zones with dialer - Grey cabinet
The Sigma A-CP range of conventional fire control panels with optional built in communicator are available with 2, 4 or 8 initiating circuits which may be extensively configured via a simple front panel operated programming method.
The low standby power requirements and cost effective small batteries allow the panel to be mounted in a small discrete enclosure which is available in standard red or optionally in an attractive grey colour.
A simple programming method using just 3 front panel buttons allows an extensive list of configuration options to be set and reviewed.
Single board construction which allows easy removal of all electronic parts by removing just 2 screws and ample provision of cable entry knockouts simplify installation.
4 Amp notification appliance power and built in selectable sync protocols provide ample power and control for a wide range of standard notification appliances.
The built in RS485 communications bus provides the facility to connect 4 wire annunciators or ancillary relay boards to provide further indication and control options throughout a premises.
The optional DACT allows dual line reporting to central stations and provides a 500 event history buffer.
FEATURES & BENEFITS
- UL864 approved
- Two, four or eight initiating circuits
- Initiating circuits individually configurable as Fire, Water flow or Supervisory
- Two 2A notification appliance circuits
- Selectable NAC sync protocols
- Two 2.0A notification appliance circuits
- 6.5A power supply
- Alarm verification selectable by zone
- Resettable Aux power output rated at 0.3A
- Aux power configurable to power off on Fire condition
- Fire, Trouble and Supervisory relays
- Single person walk test function
- Optional DACT
- Many advanced configuration options
- 72 hour standby with 7Ah batteries
- Compact enclosure
- Fire Drill capability
Recently Viewed
UL-FM 4 zone Conventional Control Panel K1844
UL/FM 4 zone Conventional Fire Alarm Control Panel Sigma A-CP K1844 Kentec
Carbon Monoxide Nitrogen Dioxide Gas Detector S2400CO-ND
Carbon Monoxide Gas Detector (CO) 0-300 ppm and Nitogen Dioxide Gas Detector (NO2) 0-30 ppm - RS485 serial output - Electrochemical cell - SMART P-1 Sensitron Dust Proof Enclosure for Car Parks S2400CO-ND
Outdoor siren with single amber beacon - polycarbonate cover AS610 UTC Fire & Security Aritech
720 TVL PICADIS Indoor IR Dome Camera DS-2CE55C2P-IRP3.6
720 TVL PICADIS Indoor IR Dome Camera lens 3.6mm DS-2CE55C2P-IRP - HIKVISION
4 Zones Gas Control Panel Sentox4+
4 Channel, two Alarm thresholds Microprocessor based Gas Control Panel for 4-20mA detectors DIN-rail mounting Sensitron SENTOX 4+ STSX4
Powdered Aerosol Fire Extinguisher GreenEX A500
Triple IR (IR3) Flame Detector - Explosion Proof enclosure 40/40C-I SharpEye Spectrex
Alarmline II Digital LHD Cable 105°C (221°F) w/ PP Sheath AD105P-0500
Digital Linear Heat Detection (LHD) cable 105°C (221°F) with Polypropylene Sheath Alarmline II, 500m - AD105P-0500 - ProReact F1077
Cordless Heat Detector Tester (Head only) SOLO 460 - No Climb
Smoke, Heat and CO Detector Test and Removal Kit 6m Testifire6201-001 No Climb products