Carbon Monoxide Gas Detector PATROL CO-DETECT
(CO) Carbon Monoxide Gas Detector 220VAC or 12-24VDC PATROL CO-DETECT Sensitron
S201xCO - (CO) Carbon Monoxide Gas Detector PATROL CO-DETECT Sensitron
The residential gas detectors series "PATROL" have been designed to offer the customers devices representing the highest technology for the detection of CO in residential premises.
Detection is performed by employing electrochemical cells for Carbon Monoxide (CODETECT).
The "PATROL" gas detectors for flammable gases offer a double alarm threshold as Pre-alarm and Alarm that generate when the preset alarm thresholds have been attained. A visual (LED) and audible (buzzer) indications warn of the potential dangerous situation while relay activates only in case the Alarm threshold has been exceeded.
Whenever either the sensor or any electronic components get damaged, a Fault condition generates, activating the corresponding warnings.
The detectors have a WD signalling for the microprocessor control system that activates if faults occur during operation Detectors "CO-DETECT" have been designed to fully comply with the European Standards for gas detection in residential environment EN 50291.
As far as "CO-DETECT" is concerned, the European Standards EN50291 requires that relay intervention be temporised as a function to the CO contents reached within a given period of time: the higher is the concentration, the sooner the relay will activate, as described in table 1.
Table 1
'CO' Concentration : 50ppm - Alarm Enabled in : 75 minutes
'CO' Concentration : 100ppm - Alarm Enabled in : 25 minutes
'CO' Concentration : 300ppm - Alarm Enabled in : Immediate
Available models:
S2015CO - Carbon Monoxide Gas Detector 220 VAC (other reference : FGT230CO)
S2016CO - Carbon Monoxide Gas Detector 12-24 VDC (other reference : FGT212CO)
TECHNICAL SPECIFICATIONS
- Models and P/N : CO DETECT S2015CO/S2016CO
- Gas detected : Carbon Monoxide
- Pre-alarm : Refer to table 1
- Alarm : Refer to table 1
- Power supply : 230 Vac or 12-24Vdc
- Consumption : 20 mA (S2015) 100 mA (S2016)
- Contacts rating : 8A, 250V
- Operating temperature : -10°C +
Recently Viewed
Carbon Monoxide Gas Detector - Dust Proof Version S2130CO
Carbon Monoxide Gas Detector, CO Gas Detector, Carbonyl Gas Detector 0-500 ppm 4-20mA - Electrochemical cell - SMART3G-C3 Sensitron Dust Proof Enclosure Version Zone 2 category 3 areas S2130CO
-
Ethane Gas Detector - Explosion Proof Enclosure Version S2602EN
Ethane Gas Detector, C2H6 Gas Detector 0-100% LFL 4-20mA - Infrared sensor - SMART3G-D2 Sensitron Explosion Proof Enclosure Version with display Zone 1 category 2 areas S2602EN
Open Path Gas Detector SafEye Quasar 904
The SafEye Quasar 900 Series is the very latest open path IR technology and detects a wide range of hydrocarbon gases – including alkanes (methane to hexane) and ethylene. Quasar 904
Linear Heat Detection System - Control Unit LWM1
Linear Heat Detection System - Alarmline Control Unit LWM1 - Kidde 22-11810-050
Ethyl Alcohol Gas Detector - Explosion Proof Enclosure Version S2654ET
Ethyl Alcohol Gas Detector, Ethanol Gas Detector 0-100% LFL 4-20mA - Infrared sensor - SMART3G-C2 Sensitron Explosion Proof Enclosure version Zone 1 category 2 areas S2654ET
Ultra Fast Multi IR Quad-Sense™ Flame Detector - Explosion Proof enclosure 40/40D-M SharpEye Spectrex
R32 Gas Detector - Explosion Proof Enclosure Version S3944R32
Difluoromethane Gas Detector, R-32 refrigerant Gas Detector, HFC-32 Gas Detector 0-2000 ppm 4-20mA - Infrared sensor - SMART3G-C2 Sensitron Explosion Proof Enclosure version Zone 1 category 2 areas S3944R32
1 Analogue Loop 16 Zones with APOLLO Protocol Addressable Fire Control Panel Small Enclosure Kentec SYNCRO AS A81161M2
UL-FM 1 Loop Fire Control Panel Apollo protocol K0850
UL/FM Analogue Addressable 1 Loop Fire Control Panel with Apollo protocol Elite RS K0850 Kentec
English (UK)
Français (FR)