Detecteur de Gaz Dioxyde de Carbone S2401CO2

Détecteur de Gaz Dioxyde de Carbone, Détecteur de Gaz CO2 0-5000 ppm 4-20mA Capteur Infrarouge SMART3-NC Sensitron Boitier IP55 Parking et Zones non classifiées S2401CO2
Description du produit

S2401CO2 - Détecteur de Gaz DIOXYDE DE CARBONE (CO2) 0-5000 ppm, 4-20mA - Capteur Infrarouge - Boitier IP55 SMART3-NC Parking et Zones non classifiées

Le détecteur de gaz S2401CO2 est utilisé pour détecter la présence de gaz Dioxyde de Carbone, CO2 en ppm.
The SMART3 NC gas detectors represent a non certified version of the SMART3G line and are ideal for non classified areas and car parks.
They employ high quality catalytic sensors, electrochemical cells or infrared sensors, that grant an excellent linearity and accuracy, besides an estimated lifetime of 4 years.

The SMART 3NC gas detectors provide a proportional 4-20mA output signal. By employing optional boards they can either communicate on a serial bus RS 485 or provide relay outputs.
In details, the available outputs are as follows:
- 4-20 mA. Proportional 4-20mA output current corresponding to the full range (LEL or ppm).
- Relay. By adding the STS3REL board, the unit is provided with 3 relays with voltage free changeover contacts. One relay is dedicated to the Fault and Watch-dog, while the remaining two relays can be associated to two out of the three available alarm thresholds.
- Serial RS485. By adding the STS.IDI interface, the detector can communicate on RS485 bus with SENTOX IDI and MULTISCAN++ gas control panels

The SMART3 NC detectors employ a powerful microprocessor that provides the following built-in features:
Self-diagnostic procedures to control the hardware and sensor correct operation.
Zero follower to maintain the detector zero point, from possible drifts caused by thermal or physical variations of the transducer.
Digital filter, employed in the digital analysis of the analog values sampled, this filter corrects temporary phenomena from causing reading errors or false alarms.
Hysteresis cycle: applied to the outputs associated to the alarm thresholds, it prevents continuous output switching when close to the threshold values.

The SMART3 NC detectors offer a fast and failsafe installation as well as an easy maintenance and calibration routine via the handheld keypad STS/CKD.

The SMART3 NC gas detectors run with a power supply at 12-24Vd and are available in IP55 rated enclosure.


  • Type de Détecteur : Détecteur de Gaz Dioxyde de Carbone, Détecteur de Gaz CO2
  • Typical use : Detectors for use with Sensitron control panels to detect toxic and flammable gases found where automotive vehicles are in operation. Suitable but not limited to car parks. To be used in non-classified areas only.
  • Power supply : 12-24 VDC (-20% +15%)
  • Proportional output : 4-20 mA (optional RS485)
  • Relay output (optional) : 3 relay outputs: 2 for Alarm and 1 for Fault (STS3REL)
  • Contacts rating : 24VDC 1A
  • Consumption at 12-24VDC : 40 mA
  • Repeatability : 5% FS
  • Storage temperature : -25°C to +60°C
  • Operating temperature : -10°C to +60°C
  • Relative humidity : 20 to 90 % non condensing RH/40°C
  • IP rating : IP55
  • Weight : 600 gr.
  • Dimensions : 100 x 180 x 65 mm
  • Sensor expected lifetime : 4 years


Nos Services

Ma Commande

Modes de Livraison

Moyens de Paiement

Service après-vente



Rechercher un produit

Nous contacter

Plan du site

Conditions des Offres Promotionnelles



Ornicom Security products

© 1989 - 2016 Ornicom Tous Droits Réservés.
5550 Alle-sur-Semois Belgium
Tel:+32 61 48 01 50
Fax:+32 61 48 01 51
E-mail: Cette adresse e-mail est protégée contre les robots spammeurs. Vous devez activer le JavaScript pour la visualiser.
Méthodes de Paiement