Centrale Détection Incendie 4 zones UL-FM K1844
Centrale Détection Incendie 4 zones conventionnelles UL/FM Sigma A-CP K1844 Kentec
K1844 - Centrale Détection Incendie UL/FM 4 zones Conventionnelles Sigma A-CP - Kentec
K1844-11 - 4 Zones Conventionnelles - boitier rouge
K1844-41 - 4 Zones Conventionnelles - boitier gris
K1854-11 - 4 Zones Conventionnelles avec transmetteur - boitier rouge
K1854-41 - 4 Zones Conventionnelles avec transmetteur - boitier gris
The Sigma A-CP range of conventional fire control panels with optional built in communicator are available with 2, 4 or 8 initiating circuits which may be extensively configured via a simple front panel operated programming method.
The low standby power requirements and cost effective small batteries allow the panel to be mounted in a small discrete enclosure which is available in standard red or optionally in an attractive grey colour.
A simple programming method using just 3 front panel buttons allows an extensive list of configuration options to be set and reviewed.
Single board construction which allows easy removal of all electronic parts by removing just 2 screws and ample provision of cable entry knockouts simplify installation.
4 Amp notification appliance power and built in selectable sync protocols provide ample power and control for a wide range of standard notification appliances.
The built in RS485 communications bus provides the facility to connect 4 wire annunciators or ancillary relay boards to provide further indication and control options throughout a premises.
The optional DACT allows dual line reporting to central stations and provides a 500 event history buffer.
FEATURES & BENEFITS
- UL864 approved
- Two, four or eight initiating circuits
- Initiating circuits individually configurable as Fire, Water flow or Supervisory
- Two 2A notification appliance circuits
- Selectable NAC sync protocols
- Two 2.0A notification appliance circuits
- 6.5A power supply
- Alarm verification selectable by zone
- Resettable Aux power output rated at 0.3A
- Aux power configurable to power off on Fire condition
- Fire, Trouble and Supervisory relays
- Single person walk test function
- Optional DACT
- Many advanced configuration options
- 72 hour standby with 7Ah batteries
- Compact enclosure
- Fire Drill capability
Produits consultés
Centrale Detection Incendie 8 Zones Conventionnelles HRZ8
Centrale détection incendie 8 Zones Conventionnelles HRZ8 Morley-IAS
Carte 16 Canaux Entree/Sortie SYNCRO IO
Carte 16 Canaux Entrée/Sortie pour Centrale de Détection Incendie Kentec SYNCRO IO K560
Module GSM pour Interphone / Parlophone extérieur InterCom GSM - ASC Global
Centrale de desenfumage 2 lignes 2 groupes 4A
Centrale modulaire de désenfumage compacte 2 lignes 2 groupes max 4A 24VDC coffret plastique RZN 4404-M D+H
Kit Testeur de détecteur de chaleur sans fil SOLO461-001 (avec 2 batteries) comprend Solo460 + 2 x Solo770 + Solo727
Detecteur PIR a double technologie 5 rideaux de 10 m DD100PI
Détecteur PIR à double technologie, 5 rideaux de 10 m, relais NFA2P insensible aux petits animaux DD100PI UTC Fire & Security
Transmetteur GSM Miniature par surveillance de Contact, 2 entrées, 8 numéros EasyCon GSM - ASC Global
Clip en V Inoxydable pour chemins de câbles - Paquet de 100 pièces - A1174
Aérosol de Test pour détecteur de monoxyde de carbone SOLOC3-001 - No Climb products
Aérosol de Test SOLO A10 150ml pour détecteur de fumée (ininflammable) SOLOA10-001 - No Climb
Français (FR)
English (UK)