Centrale Détection Incendie 2 zones UL-FM K1842
Centrale Détection Incendie 2 zones conventionnelles UL/FM Sigma A-CP K1842 Kentec
K1842 - Centrale Détection Incendie UL/FM 2 zones Conventionnelles Sigma A-CP - Kentec
K1842-11 - 2 Zones Conventionnelles - boitier rouge
K1842-41 - 2 Zones Conventionnelles - boitier gris
K1852-11 - 2 Zones Conventionnelles avec transmetteur - boitier rouge
K1852-41 - 2 Zones Conventionnelles avec transmetteur - boitier gris
The Sigma A-CP range of conventional fire control panels with optional built in communicator are available with 2, 4 or 8 initiating circuits which may be extensively configured via a simple front panel operated programming method.
The low standby power requirements and cost effective small batteries allow the panel to be mounted in a small discrete enclosure which is available in standard red or optionally in an attractive grey colour.
A simple programming method using just 3 front panel buttons allows an extensive list of configuration options to be set and reviewed.
Single board construction which allows easy removal of all electronic parts by removing just 2 screws and ample provision of cable entry knockouts simplify installation.
4 Amp notification appliance power and built in selectable sync protocols provide ample power and control for a wide range of standard notification appliances.
The built in RS485 communications bus provides the facility to connect 4 wire annunciators or ancillary relay boards to provide further indication and control options throughout a premises.
The optional DACT allows dual line reporting to central stations and provides a 500 event history buffer.
FEATURES & BENEFITS
- UL864 approved
- Two, four or eight initiating circuits
- Initiating circuits individually configurable as Fire, Water flow or Supervisory
- Two 2A notification appliance circuits
- Selectable NAC sync protocols
- Two 2.0A notification appliance circuits
- 6.5A power supply
- Alarm verification selectable by zone
- Resettable Aux power output rated at 0.3A
- Aux power configurable to power off on Fire condition
- Fire, Trouble and Supervisory relays
- Single person walk test function
- Optional DACT
- Many advanced configuration options
- 72 hour standby with 7Ah batteries
- Compact enclosure
- Fire Drill capability
Produits consultés
Centrale incendie Marine 8 zones conventionnelles ESEN-8MAR
Centrale incendie agréée Marine 8 zones conventionnelles ESEN-8MAR - HAES
Kit Externe Ventilation 'Ventline' 24VDC 1A ACX1 D+H
Centrale Gaz 64 Zones Multiscan++Park STMTSPK64B
Centrale Détection Gaz 8 Zones extensible à 64 zones pour parking boitier ABS Multiscan++Park Sensitron ST.MTS/PK64B
Détecteur de Gaz SF6 Boitier Etanche S3598SF6
Détecteur de Gaz SF6, Détecteur de Gaz Hexafluorure de soufre 0-2000 ppm 4-20mA Capteur Infrarouge SMART3G-C3 Sensitron Boitier Etanche Zone 2 Catégorie 3 S3598SF6 Sensitron
Français (FR)
English (UK)