Carte 16 Canaux Entree/Sortie SYNCRO IO
Carte 16 Canaux Entrée/Sortie pour Centrale de Détection Incendie Kentec SYNCRO IO K560
K560 - Carte 16 Canaux Entrée/Sortie pour Centrale de Détection Incendie Kentec SYNCRO IO
To add more I/O capability to the extensive options already offered by the Syncro control panel, up to thirty two, sixteen channel I/O boards may be connected.
The 16 channel boards may be mixed on the RS485 bus with 8 way sounder boards, 6 way sounder boards or 4 way conventional detection zone boards to provide a very flexible system of I/O to satisfy any requirement.
When using a simple two wire RS485 communications protocol, these boards may be mounted locally to the control panel or distributed on a bus up to 1200 metres long by using a suitable cable.
The flexibility of these boards is further enhanced by the fact that each of the channels is configurable as either an input or and output.
Each channel may also be configured to produce a variety of input actions or respond to a variety of output types.
All channels can contribute to, or respond to, system wide cause and effects logic.
Typical uses for I/O boards include geographical LED mimic displays and plant alarm inputs.
Standard Syncro control panels contain fixings for one sounder, relay, conventional detection or I/O board, which can easily be connected using four small signal wires to the power and comms bus within the panel.
Consideration must be taken as to the loading on the main panel.
FEATURES & BENEFITS
- 16 channels
- Each channel configurable as input or output
- Inputs opto-isolated
- Outputs open collector transistor
- Simple 2 wire connection to control panel
- Up to 32 boards supported per panel (512 Input/Output Channels)
- Inputs and outputs configurable as per field devices
- Full cause and effects on all inputs and outputs
- Multi drop RS485 communications
- Can be used with other Syncro I/O modules on the same panel
- Compatible with Syncro AS panels
TECHNICAL SPECIFICATIONS
- Product code : K560
- Supply voltage : 21 - 30VDC
- Quiescent current : 20mA
- Current per input : 3mA (maximum)
- Current per output : 100mA (maximum)
- Communications : RS485 two wire
- Maximum distance from panel : 1.2Km (using correct type of cable)
- PCB size : 190mm x 61mm
- Cable capacity : 2.5mm per terminal
- Operating temperature : -10°C to +50°C
- Operating humidity : To 95% (non condensing)
Produits consultés
Tableau de localisation incendie UL-FM eMatrix
Tableau de localisation incendie configurable avec plan d'étage UL/FM eMatrix Kentec
Detecteur de Gaz SF6 Boitier Antideflagrant S3601SF6
Détecteur de Gaz SF6, Détecteur de Gaz Hexafluorure de soufre 0-2000 ppm 4-20mA Capteur Infrarouge SMART3G-D2 Sensitron Boitier Antidéflagrant avec Afficheur Zone 1 Catégorie 2 S3601SF6
Bouton Poussoir Bleu + Socle RP-BS-01
Bouton poussoir Bleu avec vitre plexi incassable + Socle RP-BS-01 Vimpex
Câble Faradisé et Twisté avec une paire 1,0 mm2 prévu pour la liaison RS485, disponible en 100m et 500m - Morley-IAS - Honeywell
Détecteur de Chaleur Température Fixe 78°C Conventionnel 4351E
Gamme 300 Détecteur de Chaleur Température Fixe 78°C Conventionnel avec agrément Bosec 4351E System Sensor, Morley-IAS
Aerosol d'Extinction GreenEX A1000
Aérosol d'Extinction GreenEX A1000 GreenSol à déclenchement électrique et kit de fixation A1000
Camera Tube IR HD 2MP DS-2CD4224F-I - HIKVISION
Caméra Dome IP PTZ 1.3MP Très Basse Température DS-2DF5276-AEL
Caméra Dome IP PTZ 1.3MP Très Basse Température DS-2DF5276-AEL - HIKVISION
Centrale Detection Incendie 2 boucles Analogiques 16 Zones SYNCRO AS H81162M3
Centrale Détection Incendie Analogique SYNCRO AS 2 Boucles 16 Zones Grand Coffret Protocole HOCHIKI H81162M3
Caméra réseau Tourelle EXIR 3MP avec Infrarouge, objectif fixe 2,8 mm DS-2CD2332-I - HIKVISION
Français (FR)
English (UK)