ORNICOM



Distribution de produits de sécurité

Adresse:
Bouillon, Belgium

Courriel:
info@ornicom.com

Téléphone:
+32 477 23 76 79

 x 

Panier Vide

Sélectionnez votre langue


K21083M4 - Centrale D'extinction Incendie 8 Zones 3 Régions - 8 zones 3 areas Extinguishant Fire Control Panel SIGMA XT+K21083M4 - Centrale D'extinction Incendie 8 Zones 3 Régions - 8 zones 3 areas Extinguishant Fire Control Panel SIGMA XT+
Imprimer

Centrale d'extinction Incendie 8 Zones 3 Régions Sigma XT+ K21083M4

Centrale d'extinction Incendie Conventionnelle 8 Zones 3 Régions Sigma XT+ K21083M4 Kentec
1523,00 €
Total hors-taxes : 1523,00 €
Description du produit

K21083M4 – Centrale D'extinction Incendie Conventionnelle 8 Zones 3 Régions - SIGMA XT+ Kentec

Sigma XT+ control panels are multi-area extinguishant control panels complying with EN12094-1, EN54-2 and EN54-4. 
Up to 8 zones of conventional detection with up to 4 extinguishant areas are available.
Stand alone extinguishant control units are also available with 2 monitored inputs to receive initiating signals from remote fire detection control panels or addressable modules.

Each extinguishant area has a comprehensive set of inputs and outputs and is configurable via a simple programming interface.
All extinguishant areas may have up to 7, serially connected Sigma Si status indication and control units or ancillary relay boards connected via a simple 4 core cable.

The versatility of the control panel can be enhanced further by the fitting of up to 7 Sigma CP Ancillary boards (K580) or Sigma CP Sounder boards (K461) to the RS485 serial bus. See data sheet DS39 and DS48.

For compatible status units see Sigma Si data sheet DS41.

FONCTIONNALITES & AVANTAGES

  • Approved to EN12094-1, EN54-2 and EN54-4
  • 2, 4 or 8 detection zones
  • 1 to 4 extinguishant areas
  • Dual extinguishant outputs for each area (configurable as Main/Reserve)
  • First and second stage sounder outputs for each area
  • First and second stage volt free changeover contacts for each area
  • Released volt free contact per area
  • Fault volt free contact per area
  • Programmable extinguishant delays
  • Programmable output duration
  • Extract fan control
  • Countdown indicator shows time until release in seconds
  • Mode select and manual release controls per area
  • Monitored remote manual release input
  • Monitored remote Hold input
  • Monitored remote Mode select (door interlock) input
  • Monitored remote Released pressure switch input
  • Monitored remote Low Pressure switch input
  • Monitored Abort input
  • Serial connection for Sigma Si status units and ancillary boards. (K588)

 

 

 


Une question ?

Worldwide delivery - Livraison internationale

Livraison Internationale

Quelques mots de Nous

Ornicom s'appuie sur plus de 30 ans d'expérience pour proposer une gamme étendue et innovante de système de sécurité intégré.

En apportant une réponse personnalisée à leurs problématiques spécifiques, nous accompagnons nos clients, étape après étape, vers la réussite de leurs projets.

En Savoir Plus

 

Besoin d'un Catalogue ?

Nos Services

Ma Commande

Modes de Livraison

Moyens de Paiement

Service après-vente

 

Aide

Rechercher un produit

Nous contacter

Plan du site

Conditions des Offres Promotionnelles

 

 

 

Ornicom Security products

© 1989 - 2023 Ornicom Tous Droits Réservés.
 
6830 Bouillon, Belgique
Tel:+32 477 23 76 79
Fax:+32 61 48 01 51
E-mail: Cette adresse e-mail est protégée contre les robots spammeurs. Vous devez activer le JavaScript pour la visualiser.
 
Méthodes de Paiement
JUMP TO TOP